Code: C-1406

Description: PB non-volatile memory abnormality.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.

Code: C-1411

Description: 5V power abnormality in the SD drive board (SDDB).
Causes: SD drive board (SDDB) SD control board (SDCB)
Remedy: 1 Check the connector connection and the wiring of SDDB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 3 Replace SDDB - 4 Replace SDCB.

Code: C-1432

Description: Communication error in FD
Causes: FD control board (FDCB: FD-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB.

Code: C-1433

Description: Communication error in SD
Causes: SD control board (SDCB: SD-506)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB.

Code: C-1434

Description: Communication error in RU
Causes: RU control board (RUCB: RU-506)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of RUCB, and repair it if any abnormality. - 3 Reinstalling RU firmware - 4 Replace RUCB

Code: C-1435

Description: PB control board (PBCB) error 1. Message queue full or the control abnormality of Sub CPU1 in PBCB.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.

Code: C-1436

Description: PB control board (PBCB) error 2. Message queue full or the control abnormality of Sub CPU2 in PBCB.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.

Code: C-1437

Description: PB control board (PBCB) error 3. Message queue of the communication among tasks in the PB is full.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie