Description: Toner counter (CNT1) power abnormality 1. When CNT1 is turned ON from OFF, an error detection signal (blowout of ICP/24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Toner counter (CNT1) power abnormality 2. When CNT1 is turned ON from OFF, an error detection signal (blowout of ICP) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: Total counter (CNT1) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and CNT1, and repair it if any abnormality. - 2 Check the CNT1, and repair/replace it if any abnormality. 10-K 3 Replace CNT1 and ACDB at a time.
Description: Key counter (CNT2) power abnormality 2. When CNT2 is turned ON from OFF, an error detection signal (blowout of ICP/24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Key counter (CNT2) power abnormality 2. When CNT2 is turned ON from OFF, an error detection signal (blowout of ICP) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: Key counter (CNT2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and CNT2, and repair it if any abnormality. - 2 Check CNT2, and repair/replace it if any abnormality. 9-N 3 Replace CNT2 and ACDB at a time.
Description: Suction cooling fan /1 (FM6) rotation abnormality + 24V power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Suction cooling fan /1 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Suction cooling fan /1 (FM6) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 3 Replace FM6 and ACDB at a time.
Description: Suction cooling fan /1 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Suction cooling fan /1 (FM6) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM6. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Suction cooling fan /3 (FM8) rotation abnormality + 24V power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.