Description: Drum motor (M22) drive abnormality + 24V power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace PRCB. - 3 Replace DCPS /2.
Code: C-2208
Description: Blade motor (M22) power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected.
Causes: Blade motor (M22) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 3 Replace M22 and PRCB at a time.
Code: C-2209
Description: It is checked that the movement of the blade motor (M22) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected.
Causes: Blade motor (M22) Printer control board (PRCB)
Remedy: 1 Check the trimmer blade operation, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 4 Replace M22. - 5 Replace PRCB.
Code: C-2210
Description: The drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON.
Causes: Drum motor (M2) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 20-K 3 Replace M2. - 4 Replace PRCB.
Code: C-2211
Description: Intermediate hopper motor (M11) power abnormality. An error detection signal (blowout of ICP) is detected when M11 turns ON.
Causes: Intermediate hopper motor (M11) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 6-M 3 Replace M11 and PRCB at a time.
Code: C-2212
Description: Air separation motor (M10) power abnormality. An error detection signal (blowout of ICP) is detected when M10 turns ON.
Causes: Air separation motor (M10) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-M 3 Replace M10 and PRCB at a time.
Code: C-2213
Description: Air separation motor (M10) rotation abnormality. Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again.
Causes: Air separation motor (M10) Printer control board (PRCB)
Remedy: 1 Check the air separation section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 5-M 4 Replace M10. - 5 Replace PRCB.
Code: C-2214
Description: The toner conveyance abnormality is detected. When executing the toner supply operation for 8 minutes, the intermediate hopper toner remaining sensor (PS31) does not turn ON and the hopper toner remaining sensor /2 (PS33) detects ON in succession for 15 seconds.
Remedy: 1 Check the hopper section and the intermediate hopper section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the sensor, and repair it if any abnormality. - 3 Check the sensor, and repair/replace it if any abnormality. 4-M 6-M 4 Replace PS39. - 5 Replace PS33. - 6 Replace PRCB.