Description: Master Board failure including a unit failure of QM Coder
A reset, encoding, or decoding termination interrupt signal is not received, or an encoding or decoding error occurs.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the CCD Assy and Master Board. 3. If connections are okay, change the Master Board.
Description: Master Board failure including a unit failure of memory
The range over which data can be read from DRAM is smaller than the standard memory (16MB).
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the CCD Assy and Master Board. 3. If connections are okay, change the Master Board.
Description: Master Board failure including a unit failure of ASIC1
DMA termination interrrupt signal is not received.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the CCD Assy and Master Board. 3. If connections are okay, change the Master Board.
Description: Polygon Motor’s failure to turn
• The Lock signal remains HIGH 5 sec. after the motor has started turning. • The Lock signal does not go LOW even once for a 1sec. period at any time 1 sec. after the motor has started turning. • The Lock signal remains HIGH for a continuous 0.5sec. or more period while the motor is energized.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.
Description: Polygon Motor turning at abnormal timing
The Lock signal remains LOW for a continuous 5-sec. or more period while the motor is deenergized.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.
Description: SOS Sensor failure
After the lapse of a 5-sec. period after an SOS has been detected, no new SOS is detected.
Remedy: 1. Reset the malfunction. 2. If the malfunction is still detected, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.