Description: Paper source option Vertical Transport Cooling Fan Motor malfunction
Remedy: 1 Vertical Transport Cooling Fan Motor rotation: the voltage across PJ14A-1 on Power Supply Board and GND is DC24V after the malfunction has been reset. NO Change Control Board. 2 Vertical Transport Cooling Fan Motor rotation: the voltage across PJ14A-3 on Power Supply Board and GND is DC0V after the malfunction has been reset. YES Change Control Board. NO Check motor for installation. Change motor.
Code: C004C
Description: Ventilation Fan Motor’s failure to turn
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 Ventilation Fan Motor rotation: the voltage across PJ9A-7B on Master Board and GND is DC24V when the Start key is pressed. NO Change Master Board. 2 Ventilation Fan Motor rotation: the voltage across PJ9A-5B on Master Board and GND is DC0V when the Start key is pressed. YES Change Master Board. NO Check motor for installation. Change motor.
Code: C004E
Description: Power Supply Unit Cooling Fan Motor 1’s failure to turn
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning at high speed.
Remedy: 1 Power Supply Unit Cooling Fan Motor 1 rotation: the voltage across PJ3C-1 on Power Supply Board and GND is DC24V after the malfunction has been reset. NO Change Power Supply Board. 2 Power Supply Unit Cooling Fan Motor 1 rotation: the voltage across PJ3C-3 on Power Supply Board and GND is DC5V after the malfunction has been reset. YES Check motor for installation. Change motor. NO Change Power Supply Board.
Code: C004F
Description: Power Supply Unit Cooling Fan Motor 2’s failure to turn
The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning at high speed.
Remedy: 1 Power Supply Unit Cooling Fan Motor 2 rotation: the voltage across PJ6A-11 on Power Supply Board and GND is DC24V after the malfunction has been reset. NO Change Master Board. 2 Power Supply Unit Cooling Fan Motor 2 rotation: the voltage across PJ6A-13 on Power Supply Board and GND is DC5V after the malfunction has been reset. YES Check motor for installation. Change motor. NO Change Master Board.
Code: C0072
Description: Main Hopper Toner Replenishing Motor’s failure to turn
• The Toner Bottle Home Position Sensor does not go HIGH within 5 sec. after the motor has started turning. • The Toner Bottle Home Position Sensor does not go LOW within 10 sec. after the motor has started turning and the sensor has gone HIGH. • The motor is stationary or the Toner Bottle Home Position Sensor is HIGH 2 sec. after the motor has stopped turning.
Remedy: 1 Toner Bottle turns when the Toner Bottle is turned a half turn and the Front Door is closed. NO Correct drive coupling. 2 I/O check for Toner Bottle Home Position Sensor operation: the voltage across PJ11A-5 on Master Board and GND is DC5V (Toner Bottle at home position) and DC0V (Toner Bottle at a position other than home) when step 1 is performed. YES Change Master Board. NO Check sensor for installation. Correct detecting plate. Change sensor. 3 Main Hopper Toner Replenishing Motor rotation: the voltage across PJ11A-1 on Master Board and GND is DC0V (Toner Bottle at a stop) and DC24V (Toner Bottle turning) when step 1 is performed. YES Change motor. NO Change Master Board.
Code: C0090
Description: Developing Unit Drive Motor’s failure to turn
• The Lock signal remains HIGH for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has started turning. • The Lock signal remains LOW for a continuous period of 1.5 sec. or more after the lapse of 10 sec. after the motor has stopped turning.
Remedy: 1 Developing Unit Drive Motor rotation: the voltage across PJ7A-7A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. NO Change Master Board. 2 Developing Unit Drive Motor rotation: the voltage across PJ7A-6A on Master Board and GND is DC5V (motor deenergized) and DC0V (motor energized) when the Start key is pressed. YES Correct drive coupling. Correct installed position of the Developing Unit. Change motor. NO Change Master Board.
Code: C0210
Description: Image Transfer/Paper Separator Corona charge leak detected
The Charge Leak Detection signal (SCD) remains ON for a continuous period of 0.3 sec. after the Image Transfer/Paper Separator Corona output has been turned ON.
Remedy: 1 The Image Transfer/Paper Separator Coronas Unit is installed properly. NO Correct installed position. 2 The Image Transfer/Paper Separator Coronas wires are dirty or have snapped. YES Clean or change. 3 The malfunction code appears even with PJ2HV1 unplugged. YES Change Master Board. NO Change the HV.
Code: C0400
Description: Exposure Lamp’s failure to turn ON
• During a light intensity adjustment sequence, the CCD read data does not exceed the specified level when the peak of the intensity of light is detected within 1 min. after the Exposure Lamp has turned ON. • Under normal conditions, the CCD read data does not exceed the specified level 450 ms after the Exposure Lamp has turned ON.
Remedy: 1 Exposure Lamp has discolored. YES Change Exposure Lamp. 2 NG is displayed when “Scanning Check” of Function (IR) is run. YES Check the optical path. Change Image Processing Board or CCD Board. 3 Power Supply Board operation: the voltage across PJ9C-4 on Power Supply Board and GND is DC24V after the malfunction has been reset. YES Check and change, as necessary, flat cable. Change Inverter Board or Image Processing Board. NO Change Power Supply Board.