Description: 2nd image transfer pressure/ retraction failure
• The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A. 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
Description: 1st image transfer pressure/ retraction failure
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C. 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
Description: Polygon Motor malfunction
• The Polygon Motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Polygon Motor is being rotated.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
Description: Heating Roller warm-up failure
• The Heating Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
Description: Fusing Pressure Roller warm-up failure
• The Fusing Pressure Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
Description: Abnormally low Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains lower than the specified value for a given period of time or longer.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
Description: Abnormally low Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains lower than the specified value for a given period of time or longer.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.