Các lỗi thường gặp

Code :
  • Code: 0094H
  • Description: 2nd image transfer pressure/ retraction failure
    • The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A. 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
  • Code: 0096H
  • Description: 1st image transfer pressure/ retraction failure
    • The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C. 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.
  • Code: 0300H
  • Description: Polygon Motor malfunction
    • The Polygon Motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The Motor Lock signal remains HIGH for a given period of consecutive time while the Polygon Motor is being rotated.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
  • Code: 0310H
  • Description: Laser malfunction
    • The SOS signal is not detected within a given period of time after the output of the laser has been started.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
  • Code: 0500H
  • Description: Heating Roller warm-up failure
    • The Heating Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
  • Code: 0501H
  • Description: Fusing Pressure Roller warm-up failure
    • The Fusing Pressure Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
  • Code: 0510H
  • Description: Abnormally low Heating Roller temperature
    • The temperature detected by the Heating Roller Thermistor remains lower than the specified value for a given period of time or longer.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.
  • Code: 0511H
  • Description: Abnormally low Fusing Pressure Roller temperature
    • The temperature detected by the Fusing Pressure Roller Thermistor remains lower than the specified value for a given period of time or longer.
  • Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary. 3 Change Fusing Unit. 4 Change PWB-A. 5 Change LV.