Code :
  • Code: 2010
  • Description: Main motor start-up error The ready signal was not detected when passing 2s after the main motor is started up.
  • Remedy: Wire and connector between the main motor and main/engine PWB (YC9) If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity.
    Main motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage.
    Main motor Replace the main motor.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 2600
  • Description: PF conveying motor error (Paper feeder) The ready signal is not detected within 2s after the PF conveying motor of the cassette 2 turns on.
  • Remedy: Connection of the wire and connector PF conveying motor - PF main PWB If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity.
    PF conveying motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage.
    PF conveying motor Replace the PF conveying motor.
  • Code: 2610
  • Description: PF conveying motor error (Paper feeder) The ready signal is not detected within 2s after the PF conveying motor of the cassette 3 turns on.
  • Remedy: Connection of the wire and connector PF conveying motor - PF main PWB If the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if there is no continuity.
    PF conveying motor drive transmission system Check if each roller and gear rotate smoothly. Apply grease to the bushings and gears if they are faulty. Check each gear if it is damaged and replace it if there is damage.
    PF conveying motor Replace the PF conveying motor.
  • Code: 3100
  • Description: Carriage error 1) While the HP sensor is interrupted at the initial drive, it is not released when driven by 66.1mm toward the scanning direction 2) During the initial drive while the HP sensor is released, the HP sensor is not interrupted when driving it by 379.5mm toward the return direction
  • Remedy: Scanner motor 1. Move the scanner manually to check if there is too much load. 2. Check that the scanner drive belt is not disengaged. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Scanner motor - Main/engine PWB (YC31) 4. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 5. Replace the scanner motor.
    Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected, Insert the connector all the way in. Home position sensor - Main/engine PWB (YC17) 3. Replace the home position sensor.
    CIS Replace the scanner carriage and execute U411.
    Main/ Engine PWB Replace the main/engine PWB.
  • Code: 3200
  • Description: CIS lamp error The white reference data obtained when the lamp is turned on at the time of initialization is lower than the rated value.
  • Remedy: CIS Replace the scanner carriage and execute U411.
    Main/ Engine PWB Replace the main/engine PWB.
  • Code: 3210
  • Description: DP CIS lamp error The white reference data obtained when the lamp is turned on at the time of initialization is lower than the rated value. (40 ppm model only)
  • Remedy: DP CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPCIS - Main/Engine PWB(YC509) 2. Replace DPCIS and execute U411.
  • Code: 3300
  • Description: CIS AGC error An error was detected when processing the front side AGC
  • Remedy: CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS - Main/Engine PWB (YC506) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the scanner carriage and execute U411
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3310
  • Description: DP CIS AGC error An error was detected when processing the back side AGC (40 ppm model only)
  • Remedy: DP CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPCIS - Main/Engine PWB(YC509) 2. Replace DPCIS and execute U411.
    Main/Engine PWB Replace the main/engine PWB.