Description: Developing motor MCY error The ready signal cannot be detected within 5 seconds after the developing motor MCY turns on.
Causes: Defective harness between developing motor MCY and engine PWB (YC27), or improper connector insertion. Defective drive transmission system of the developing motor MCY. Defective developing motor MCY. Defective engine PWB.
Remedy: Defective harness between developing motor MCY and engine PWB (YC27), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the developing motor MCY. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective developing motor MCY. Replace the developing motor MCY. Defective engine PWB. Replace the engine PWB.
Description: Drum motor K error The ready signal cannot be detected within 5 seconds after the drum motor K turns on.
Causes: Defective harness between drum motor K and engine PWB (YC608), or improper connector insertion. Defective drive transmission system of the drum motor K. Defective drum motor K. Defective engine PWB.
Remedy: Defective harness between drum motor K and engine PWB (YC608), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the drum motor K. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective drum motor K. Replace the drum motor K. Defective engine PWB. Replace the engine PWB.
Description: Drum motor C error The ready signal cannot be detected within 5 seconds after the drum motor C turns on.
Causes: Defective harness between drum motor C and engine PWB (YC608), or improper connector insertion. Defective drive transmission system of the drum motor C. Defective drum motor C. Defective engine PWB.
Remedy: Defective harness between drum motor C and engine PWB (YC608), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the drum motor C. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective drum motor C. Replace the drum motor C. Defective engine PWB. Replace the engine PWB.
Description: Drum motor M error The ready signal cannot be detected within 5 seconds after the drum motor M turns on.
Causes: Defective harness between drum motor M and engine PWB (YC608), or improper connector insertion. Defective drive transmission system of the drum motor M. Defective drum motor M. Defective engine PWB.
Remedy: Defective harness between drum motor M and engine PWB (YC608), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the drum motor M. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective drum motor M. Replace the drum motor M. Defective engine PWB. Replace the engine PWB.
Description: Drum motor Y error The ready signal cannot be detected within 5 seconds after the drum motor Y turns on.
Causes: Defective harness between drum motor Y and engine PWB (YC608), or improper connector insertion. Defective drive transmission system of the drum motor Y. Defective drum motor Y. Defective engine PWB.
Remedy: Defective harness between drum motor Y and engine PWB (YC608), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the drum motor Y. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective drum motor Y. Replace the drum motor Y. Defective engine PWB. Replace the engine PWB.
Description: Fuser motor error The ready signal cannot be detected within 5 seconds after the fuser motor turns on.
Causes: Defective harness between fuser motor and engine PWB (YC605), or improper connector insertion. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB.
Remedy: Defective harness between fuser motor and engine PWB (YC605), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the fuser motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective fuser motor. Replace the fuser motor. Defective engine PWB. Replace the engine PWB.
Description: Fuser pressure change motor (overcurrent) error When the fuser pressure change motor is driven, the fuser pressure change motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals.
Causes: Defective harness between fuser pressure change motor and engine PWB (YC615), or improper connector insertion. Defective drive transmission system of the fuser pressure change motor. Defective fuser pressure change motor. Defective engine PWB.
Remedy: Defective harness between fuser pressure change motor and engine PWB (YC615), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the fuser pressure change motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective fuser pressure change motor. Replace the fuser pressure change motor. Defective engine PWB. Replace the engine PWB.
Description: Fuser pressure change motor (timeout) error After the fuser pressure change motor is driven, the ON status of the fuser pressure change sensor cannot be detected for 6 seconds.
Causes: Defective harness between fuser pressure change motor and paper exit PWB (YC8), or improper connector insertion. Defective fuser pressure change sensor. Defective engine PWB. Defective paper exit PWB.
Remedy: Defective harness between fuser pressure change motor and paper exit PWB (YC8), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective fuser pressure change sensor. Replace the fuser pressure change sensor. Defective engine PWB. Replace the engine PWB. Defective paper exit PWB. Replace the paper exit PWB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.