Description: 2nd Image Transfer Roller pressure/retraction failure
• The 2nd Image Transfer Pressure Position Sensor is not activated (retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its retracting motion. • The 2nd Image Transfer Pressure Position Sensor is not deactivated (not the retracted position) within 1 sec. after the 2nd Image Transfer Roller has started its pressing motion.
Remedy: 1 While the 2nd Image Transfer Pressure/ Retraction Clutch is supposed to be deenergized during timing of pressure/retraction operation: the voltage across PJ14I-9A on Master Board and GND is DC 24 V when the clutch is deenergized and DC 0 V when the clutch is energized. YES: Check connector for connection. Check for overload. Change clutch. NO: Change Master Board. 2 I/O check for 2nd Image Transfer Pressure Position Sensor operation during pressure/ retraction operation: the voltage across PJ14I-6B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.
Description: 1st Image Transfer Roller pressure/retraction failure
• The 1st Image Transfer Retraction Position Sensor is not activated (retracted position) within 3 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning. • The 1st Image Transfer Retraction Position Sensor is not deactivated (pressed position) within 1.5 sec. after the 1st Image Transfer Pressure/Retraction Motor has started turning.
Remedy: 1 1st Image Transfer Pressure/Retraction Motor turns during pressure/retraction operation. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). Change motor. Change Master Board. 2 I/O check for 1st Image Transfer Retraction Position Sensor operation during pressure/ retraction operation: the voltage across PJ17I-1A on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (retracted position). YES: Change Master Board. NO: Correct actuator. Check sensor connector for connection. Change sensor.
Description: Fusing Roller pressure/ retraction failure
• No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for retraction direction during retraction control. • No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 31 motor encoder pulses have been counted after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control.
Remedy: 1 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is retracted: the voltage across PJ14I-4A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. YES: Check motor connector for connection. Change motor. NO: Change Master Board. 2 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is retracted: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked (retracted position) and DC 5 V when the sensor is blocked. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 3 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is pressed: the voltage across PJ14I-5A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change Master Board. 4 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is pressed: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 5 I/O check for Fusing Retraction Position Sensor operation while the Fusing Pressure/ Retraction Motor is turning: the voltage across PJ17I-3B on Master Board and GND remains DC 0 V when the sensor is unblocked or remains DC 5 V when the sensor is blocked while the motor remains stationary, and alternates between DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked while the motor is turning. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor.
Description: Cyan PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON).
Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
Description: Magenta PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON).
Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
Description: Yellow PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON).
Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
Description: Black PC Drum Charge Corona malfunction
The SCD signal remains inactive for a continuous 1sec. period while charge corona is being output (i.e., the Remote signal is being turned ON).
Remedy: 1 Imaging Unit contact failure YES: Correct or clean Imaging Unit contact. 2 High Voltage Unit 1 contact failure YES: Correct or clean High Voltage Unit 1 contact. 3 After corona output has been turned ON: Cyan (C0200): The voltage across PJ9I-10 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Magenta (C0202): The voltage across PJ9I-8 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Yellow (C0204): The voltage across PJ9I-6 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. Bk (C0206): The voltage across PJ9I-12 on Master Board and GND is DC 24 V when the output is turned OFF and DC 0 V when the output is turned ON. YES: Change High Voltage Unit 1. NO: Change Master Board.oard.
Description: Exposure Lamp’s failure to turn ON
A Lamp-Out Detection signal is ON after the lapse of 5 sec. after the Exposure Lamp has been turned ON.
Remedy: 1 Exposure Lamp conduction NO: Change Exposure Lamp. 2 Temperature Fuse conduction. NO: Change Temperature Fuse. 3 Flat Cable conduction NO: Check for correct installation or change. 4 The problem has been eliminated through the checks of steps up to 3. NO: Change DC Power Supply 2. 5 Exposure Lamp turns ON and OFF correctly after DC Power Supply 2 has been replaced. NO: Change Image Processing Board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.