Description: Cyan ATDC Sensor adjustment failure
Cyan ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Code: C0F3B
Description: Magenta ATDC Sensor adjustment failure
Magenta ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Code: C0F3C
Description: Yellow ATDC Sensor adjustment failure
Yellow ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 ATDC Sensor window is dirty. YES: Clean. 2 Imaging Unit window for ATDC Sensor is dirty. YES: Clean. 3 LED retracting lever is locked in position. NO: Slide out the Imaging Unit and then reinstall. 4 The problem has been eliminated through the checks of steps up to 3. NO: Check ATDC Sensor connector. Change ATDC Sensor. 5 The problem is eliminated after the ATDC Sensor has been replaced. NO: Change Imaging Unit. 6 The problem is eliminated after the Imaging Unit has been replaced. NO: Change Master Board.
Code: C0F3D
Description: Black ATDC Sensor adjustment failure
Black ATDC Sensor adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Malfunction code C0F3D is displayed. YES: Change Imaging Unit. 2 The problem is eliminated after the Imaging Unit has been replaced. NO: Check harness. Check connector for connection. Change Master Board
Code: C13C8
Description: New Transfer Belt Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. After an image stabilization sequence is completed, the fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 2 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of three cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a third time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Code: C13CA
Description: New Fusing Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Code: C13CB
Description: New Fusing Web Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.
Code: C13CC
Description: New Oil Coating Unit resetting failure
The output from the new unit detecting terminal remains HIGH and the copier does not recognize that a new unit has been installed. 1. The fuse blowout signal of the new unit is set to a blowout state. 2. After the lapse of 0.5 sec. after step 1, the fuse blowout signal is brought to a state where no new units are installed. 3. After the lapse of 0.1 sec. after step 2, a new unit check sequence is carried out. A total of two cycles of steps 1 to 3 are carried out and, if the copier fails to detect a new unit a second time, a malfunction condition results.
Remedy: 1 Each unit is installed properly in the copier (good contact connection). YES: Change Master Board. NO: Reinstall.