Các lỗi thường gặp

Code :
  • Code: 1020
  • Description: Lift motor 2 error
    After cassette 2 is inserted, PF lift sensor 2 does not turn on within 15s. This error is detected five times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor 1. Defective lift motor. Defective PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair any problem that is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity of the connector cable. If necessary, replace the cable. Lift motor 2 and Engine connect PWB (YC16) Engine connect PWB (YC2) and Engine PWB (YC4)
    Defective drive transmission system of the PF lift motor 1. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if necessary.
    Defective lift motor. Replace the PF lift motor 2.
    Defective PWB. Replace the engine connect PWB or the main PWB and check for correct operation.
  • Code: 1030
  • Description: PF lift motor 1 error (paper feeder)
    After cassette 3 is inserted, PF lift sensor 1 does not turn on within 15 s. This error is detected five times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor 1. Defective PF lift motor 1. Defective PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity of the connector cable. If necessary, replace the cable. PF lift motor 1 and PF main PWB (YC4)
    Defective drive transmission system of the PF lift motor 1. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor 1. Replace the PF lift motor 1.
    Defective PWB. Replace the PF main PWB (Refer to the service manual of the paper feeder).
  • Code: 1040
  • Description: PF lift motor 2 error (paper feeder)
    After cassette 4 is inserted, PF lift sensor 2 does not turn on within 15 s. This error is detected five times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor 2. Defective PF lift motor 2. Defective PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity of the connector cable. If necessary, replace the cable. PF lift motor 2 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor 2. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor 2. Replace the PF lift motor 2.
    Defective PWB. Replace the PF main PWB (Refer to the service manual of the paper feeder).
  • Code: 1100
  • Description: PF lift motor 1 error (large capacity feeder)
    After cassette 3 is inserted, PF lift sensor 1 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 1s or more 5 times successively. However, the first 1 s after PF lift motor 1 is turned on is excluded from detection.
  • Causes: PF Lift motor1. PF Lift sensor1. PF main PWB
  • Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 1 and PF main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF lift motor1.
    PF Lift sensor1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 1 and PF main PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift sensor1.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1110
  • Description: PF lift motor 2 error (large capacity feeder)
    After cassette 4 is inserted, PF lift sensor 2 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 1s or more 5 times successively. However, the first 1 s after PF lift motor 2 is turned on is excluded from detection.
  • Causes: Paper feeder lift base elevating mechanism. PF Lift motor 2. PF Lift sensor2. PF main PWB
  • Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 2 and PF main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF Lift motor2.
    PF Lift sensor2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 2 and PF main PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift sensor 2.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1800
  • Description: Paper feeder communication error
    A communication error is detected 10 times in succession
  • Causes: Improper installation of the paper feeder. Defective connector cable or poor contact of the connector. Defective PWB.
  • Remedy: Improper installation of the paper feeder. Follow the installation instruction carefully again.
    Defective connector cable or poor contact of the connector. Reinsert the connector. Also check for continuity of the connector cable. If necessary, replace the cable. PF main PWB (YC3) and engine connect PWB (YC15) Engine connect PWB and engine PWB (YC4)
    Defective PWB. Replace the engine PWB or the PF main PWB.
  • Code: 1900
  • Description: Paper feeder EEPROM error
    When writing the data, the write data and the read data is not continuously in agreement 4 times
  • Causes: Defective PWB. Device damage of EEPROM.
  • Remedy: Defective PWB. 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB (Refer to the service manual for the paper feeder).
    Device damage of EEPROM. Contact the Service Administrative Division.
  • Code: 2101
  • Description: Developer motor K steadystate error
    The rated speed signal detected the stability OFF continuously for 1 s after the developer motor K stabilizes.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity of the connector cable. If necessary, replace the cable. Developer motor K and engine PWB (YC17)
    Defective drive transmission system. 1. To check the motor operation, execute DLP(K) by U030. 2. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if necessary.
    Defective motor. Replace the Developer motor K.
    Defective PWB. 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB and check for correct operation.
 < 1 2 3 4 5 6 7 >  Last ›