Các lỗi thường gặp

Code :
  • Code: 2610
  • Description: Paper feeder 2 Drive motor error During the motor drive, the ready signal is not turned H for continuous 2 s.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. PF drive motor - PF main PWB(YC8) Drive transmission system for the PF drive motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found. PF drive motor Replace the PF drive motor. PF main PWB Replace the PF main PWB.
  • Code: 2700
  • Description: 3-color release error In case the position signal does not change when passing 5s after the transfer belt release was switched.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Transfer release motor - Engine PWB(YC10): 30 ppm model - Engine PWB(YC17): 35/40 ppm models
    Drive transmission system for the transfer release motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
    Transfer release motor Replace the transfer release motor.
    Engine PWB Replace the engine PWB.
  • Code: 2760
  • Description: Transfer motor startup error After the motor starting, the stable signal is not turned ON within 2 s.
  • Remedy: Primary transfer unit 1. Check that the belt can be rotated by hand, and if it is locked, remove the cause. 2. Replace the primary transfer unit.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Transfer motor - Engine PWB(YC15): 30 ppm model - Engine PWB(YC22): 35/40 ppm models
    Drive transmission system for the transfer motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
    Transfer motor Replace the transfer motor.
    Engine PWB Replace the engine PWB.
  • Code: 2820
  • Description: Transfer motor steadystate error After the motor is stabilized, the ready signal is turned OFF for continuous 1 s.
  • Remedy: Primary transfer unit 1. Check that the belt can be rotated by hand, and if it is locked, check for foreign objects such as jammed paper, and if jammed, remove it. 2. Replace the primary transfer unit.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Transfer motor - Engine PWB(YC15): 30 ppm model - Engine PWB(YC22): 35/40 ppm models
    Drive transmission system for the transfer motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
    Transfer motor Replace the transfer motor.
    Engine PWB Replace the engine PWB.
  • Code: 3100
  • Description: Carriage error When turning the power on, or when the reading of the original document by table or DP scanning has completed, the home position sensor is not turned off, even if the home position sensor is on and the scanner carriage moves to the scanning direction. Or, the home position sensor does not turn on, even if the home position sensor is off and the scanner carriage moves to the return direction.
  • Remedy: Scanner motor 1. Move the scanner by hand to check whether it smoothly moves. 2. Check that the scanner drive belt is not disengaged. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Scanner motor - Engine PWB(YC19): 30 ppm model - Engine PWB(YC27): 35/40 ppm models 4. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 5. Replace the scanner motor.
    Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Home position sensor - CCD PWB (YC3) CCD PWB - Main PWB(YC2014): 30 ppm model - Engine PWB(YC5): 35/40 ppm models 3. Replace the home position sensor.
    CCD PWB 1. Replace scanner carriage. 2. Execute the U411 Adjusting the scanner automatically.
    Main PWB Replace the main PWB.
    Engine PWB Replace the engine PWB.
  • Code: 3200
  • Description: Lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value.
  • Remedy: LED PWB Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LED PWB - CCD PWB (YC2) CCD PWB - Main PWB(YC2014): 30 ppm model - Engine PWB(YC5): 35/40 ppm models
    Mirror Replace the image scanner carriage and execute U411 if the mirror is dropped off by drop shock.
    CCD PWB Replace the image scanner carriage and execute U411.
    Main PWB Replace the main PWB.
    Engine PWB Replace the engine PWB.
  • Code: 3210
  • Description: CIS lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value. (35/40 ppm model only)
  • Remedy: CIS 1. Execute the U906 resetting the partial operation. 2. Execute [CIS] in the U061 lamp lighting check. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS - DPSHD PWB (YC2,5) DPSHD PWB (YC1) - Engine PWB (YC7) 4. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 5. Replace CIS and execute U091 and U411.
    DPSHD PWB Replace the SPSHD PWB.
  • Code: 3300
  • Description: CCD AGC error In case a normal input could not be obtained from the CCD at AGC.
  • Remedy: LED lamp PWB 1. Execute [CCD] in the U061 lamp lighting check. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LED PWB - CCD PWB (YC2) CCD PWB (YC1) - Engine PWB (YC5) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 4. Replace the image scanner carriage and execute U411.
    CCD PWB Replace the image scanner carriage and execute U411.
    Engine PWB Replace the engine PWB.