Các lỗi thường gặp

Code :
  • Code: 3210
  • Description: CIS lamp error When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Execute CCD of U061 lamp check. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and DPSHD PWB (YC2) DPSHD PWB (YC3) and DP relay PWB (YC2) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the CIS and execute U091 and U411.
    DPSHD PWB Replace the DPSHD PWB.
    DP relay PWB Replace the DP relay PWB.
  • Code: 3220
  • Description: CCD lamp activation error The threshold is calculated for colors at initialization and the pixel which does not exceed that value is greater than 1000.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and Main PWB (YC11) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. If the LED lamp won’t light, replace the LED PWB and execut U411.
    ISC PWB Replace the ISC PWB and execute U411.
    Main PWB Replace the main PWB.
  • Code: 3300
  • Description: Optical system (AGC) error One of the gains is FF or 00 during the CCD lamp AGC is being processed.
  • Remedy: LED lamp PWB 1. To check the lamp, execute U061 CCD. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and Main PWB (YC11) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. If the LED lamp won’t light, replace the LED PWB and execut U411.
    CCD PWB Replace the ISU and execute U411.
    ISC PWB Replace the ISC PWB and execute U411.
    Main PWB Replace the main PWB.
  • Code: 3310
  • Description: CIS AGC error After AGC, correct input is not obtained at CIS.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. To check the lamp, execute U061 CCD. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP CIS and DPSHD PWB (YC2) DPSHD PWB (YC3) and DP relay PWB (YC2) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the CIS and execute U091 and U411.
    DPSHD PWB Replace the DPSHD PWB.
  • Code: 3500
  • Description: Communication error between scanner and ASIC An error code is detected.
  • Remedy: ISC PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. ISC PWB (YC3) and Main PWB (YC11) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the ISC PWB and execute U411.
    Main PWB Replace the main PWB.
  • Code: 3600
  • Description: Scanner sequence error
  • Remedy: ISC PWB 1. Execute U021 memory initializing. 2. Replace the ISC PWB and execute U411.
  • Code: 3700
  • Description: Scanner device error
  • Remedy: CCD (ISU) Since the ISU is mounted with a CCD of different type, install the ISU that matches with the model.
  • Code: 3800
  • Description: AFE error When writing the data, read and write data does not match 3 times in succession. No response is received in 100 ms from AEF.
  • Remedy: ISC PWB 1. Confirm that the FFC wiring connector is not distorted and connect the FFC wiring all the way in. CCD PWB (YC2) and ISC PWB (YC9) 2. If the FFC wiring is disconnected, replace the FFC wiring. 3. Replace the ISC PWB and execute U411.
    CCD PWB Replace the ISU and execute U411.