Các lỗi thường gặp

Code :
  • Code: 126.01, 126.02
  • Description: 126.01 Line Frequency outside operating range of device 126.02 No line frequency detected
  • Remedy: Step 1 Reset the machine. Does the error remain? Replace the LVPS. See “LVPS removal”. Go to step 2. Problem resolved.
    Step 2 Reset the machine. Does the error remain? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 130.01
  • Description: Transfer servo error
  • Remedy: Reset the machine. If the error remains, replace the imaging unit.
  • Code: 133.05...133.08
  • Description: 133.05 Toner Level Sensing reading above maximum expected value 133.06 Toner Level Sensing reading below minimum expected value 133.07 Toner failed to replenish into the Imaging Unit 133.08 Excessive toner level sensing noise
  • Remedy: Step 1 Ensure that the toner cartridge is installed properly. Is the toner cartridge properly installed? Go to step 2. Reinstall the toner cartridge properly.
    Step 2 Remove the existing toner cartridge and install a different cartridge. Does the error remain? Go to step 3. Problem resolved.
    Step 3 Ensure the cable for socket “JCTLS” on the controller board is properly connected. Is the above connection properly connected? Go to step 4. Reseat the connection or replace the cable. Go to the next step.
    Step 4 Ensure the toner low / imaging unit high voltage contact is free from damage. Is the toner low / imaging unit high voltage contact free from damage? Go to step 5. Replace the toner low / imaging unit high voltage contact. Go to step 5.
    Step 5 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 140.10...146.00
  • Description: 140.10 Main drive motor halls not detected 140.20 Main drive motor took too long to stop 140.30 Main drive motor unable To lock (before motor ID) 140.40 Main drive motor over speed detected 140.60 Main drive motor unable to lock (after motor ID) 140.70 Main drive motor out of lock Detected 140.80 Main drive motor excessive PWM / Overtemp 146.00 Media feeder encoder never detected in tray 1
  • Remedy: Step 1 Ensure the cable for socket “TRANSPORT MTR” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
    Step 2 Reset the machine. Does the error continue? Replace the main drive motor. See “Main drive motor removal”. Go to step 3. Problem resolved
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 149.00, 150.00
  • Description: 149.00 Redrive motor encoder never detected 150.00 Duplex motor encoder never detected
  • Remedy: Step 1 Ensure the cable for socket "REDRIVE” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connection.
    Step 2 Reset the machine. Does the error continue? Replace the upper redrive. See “Upper redrive removal”. Go to step 3. Problem resolved.
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 155.00...171.07
  • Description: 155.00 Toner add motor encoder never detected 171.03 Main cooling fan error; error took too long to ramp up 171.04 Main cooling fan error; error under speed or stalled during speed adjustment state 171.05 Main cooling fan error; error over speed during speed adjustment state 171.06 Main cooling fan error; error capture data is invalid and speed control is at maximum in fan control idle state 171.07 Main cooling fan error; error capture data is invalid and speed control is at maximum in fan control adjustment state
  • Remedy: Step 1 Ensure the cable for socket "M FAN” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connection.
    Step 2 Reset the machine. Does the error continue? Replace the duplex motor. See “Duplex motor removal”. Problem resolved.
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 172.03...173.07
  • Description: 172.03 Cartridge cooling fan took too long to ramp up 172.04 Cartridge cooling fan under speed or stalled during speed adjustment state 172.05 Cartridge cooling fan over speed during speed adjustment state 172.06 Cartridge cooling fan capture data is invalid and speed control is at maximum in fan control idle state 172.07 Cartridge cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state 173.03 LVPS cooling fan took too long to ramp up 173.04 LVPS cooling fan under speed or stalled during speed adjustment state 173.05 LVPS cooling fan over speed during speed adjustment state 173.06 LVPS cooling fan capture data is invalid and speed control is at maximum in fan control idle state 173.07 LVPS cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state
  • Remedy: Step 1 Ensure the LVPS cooling fan cable is properly connected. Is the above cable properly connected? Go to step 2. Reseat the connection.
    Step 2 Reset the machine. Does the error continue? Replace the LVPS fan with cable. Go to step 3. Problem resolved.
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
  • Code: 174.03...175.07
  • Description: 174.03 HVPS cooling fan took too long to ramp up 174.04 HVPS cooling fan under speed or stalled during speed adjustment state 174.05 HVPS cooling fan over speed during speed adjustment state 174.06 HVPS cooling fan capture data is invalid and speed control is at maximum in fan control idle state 174.07 HVPS cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state 175.03 Miscellaneous cooling fan took too long to ramp up175.04 Miscellaneous cooling fan under speed or stalled during speed adjustment state 175.05 Miscellaneous cooling fan over speed during speed adjustment state 175.06 Miscellaneous cooling fan capture data is invalid and speed control is at maximum in fan control idle state 175.07 Miscellaneous cooling fan capture data is invalid and speed control is at maximum in fan control adjustment state
  • Remedy: Step 1 Ensure the miscellaneous cooling fan cable is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connection.
    Step 2 Reset the machine. Does the error continue? Replace the HVPS fan with cable. Go to step 3. Problem resolved.
    Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.