Causes: The Set Clamp Home Sensor is not turned OFF within the specified time after the Set Clamp ends operating
Code: H5-86
Description: Side Registration Sensor OFF Fail
Causes: The Side Registration Sensor is not turned OFF within 500 ms after the Puncher Move Motor is ON. Or the Side Registration Sensor is turned ON again after the Side Registration Sensor is turned OFF and the Puncher stopped its moving. Or the Or the Side Registration Sensor1 or the Side Registration Sensor2 to be targeted is not turned OFF when the Puncher Move Motor starts operating.
Code: H5-9
Description: CRU Fan defect
Causes: A defect in the CRU FAN was detected.
Code: H5-91
Description: Stapler Fail
Causes: The OFF-ON status of the Stapler Home Sensor is not detected within the specified time after the Stapler Move Motor is ON (Forward operation). Or the Stapler Home Sensor is not turned ON within the specified timer after the Stapler Move Motor is ON (Reverse operation).
Code: H5-95
Description: Stapler Move Position SENSOR ON Fail
Causes: The Staple Move Position Sensor is not turned ON within two seconds after the Stapler starts moving toward the Staple position and also the Staple Move Position Sensor is OFF. Or the Staple Move Position Sensor is not turned ON after the Stapler was moved to the Staple position. Or the Stapler Move Position Sensor is turned OFF again after the Stapler Move Position Sensor is turned ON and the Stapler stopped its moving.
Code: H5-96
Description: Stapler Move Position SENSOR OFF Fail
Causes: The Staple Move Position Sensor is not turned OFF within 500 ms after Stapler starts moving to the Staple Position and Staple Move Position Sensor is OFF. Or the Staple Move Position Sensor is not turned OFF after the Stapler was moved to the Staple position. Or the Stapler Move Position Sensor is turned ON again after the Stapler Move Position Sensor is turned OFF and the Stapler stopped its moving.
Code: H6-4
Description: HCF NVM R/W Error
Causes: A read/write error has occurred on the NVM of the HCF PWB.
Code: H6-7
Description: HCF NVM R/W Error
Causes: A communication error occurred between the PWBA MCU F and the HCF.