Các lỗi thường gặp

Code :
  • Code: J8-2
  • Description: MCU Toner Cartridge CRUM Data Write fail
  • Causes: A data write error occurred on the XERO CRUM Tag in the Toner Cartridge.
  • Code: J8-3
  • Description: Toner Cartridge CRUM ID fail
  • Causes: A Toner Cartridge of a different specification is attached.
  • Code: U0-1
  • Description: Main Motor stop error
  • Causes: Due to the malfunction in the control system of the PWBA MCU F, the Main Motor does not stop when paper is not transported.
  • Code: U0-2
  • Description: Image Ready error
  • Causes: The PWBA MCU F does not receive the image-ready signal from the PWBA ESS at the specified timing.
  • Code: U1-1
  • Description: Main Motor fail
  • Causes: The Main Motor does not rotate at the specified speed.
  • Code: U1-4
  • Description: Drum Motor fail
  • Causes: The Drum Motor does not rotate at the specified speed.
  • Code: U3-3
  • Description: Laser Power fail
  • Causes: Light intensity of the LD2 is less than the specified value.
  • Code: U3-5
  • Description: ROS Motor fail
  • Causes: -Rotation speed of the ROS motor is less than the specified value even when the specified time is passed after the motor starts rotating. - Light intensity of the LD1 is less than the specified value.