Remedy: Is the error message displayed again? If the RAM DIMM is mounted, remove it and turn the power supply off/ON. Replace M32 board Remount RAM DIMM Replace RAMDIMM
Code: 030
Display: Service call 030: Error
Description: CU RAM Check Error
Remedy: Is the error message displayed again? Yes Power supply OFF/ON Replace M32 board
Code: 031
Display: Service call 031: Error
Description: CU Optical RAM Check Error
Remedy: Is RAM DIMM mounted normally? Does it restore by exchanging RAM DIMM? Remount RAM DIMM Replace RAMDIMM Replace M32 board
Code: 040
Display: Service call 040: Error
Description: CU EEPROM Error
Remedy: Is the error message displayed again? Yes Power supply OFF/ON Replace M32 board
Code: 041
Display: Service call 041:Error
Description: CU Flash Error Flash ROM Error on the CU board
Remedy: Is the error message displayed again? Yes Power supply OFF/ON Replace M32 board
Code: 042, 043
Display: Service call 042: Error - 043: Error
Description: Flash File System Error
Remedy: It failed to the access to CU Flash ROM that is attached to the M32 board directly. The compulsive initialization of Flash is done. (Because NICFirmware is deleted, please be careful to it. After initialization, it is necessary to write NIC-Firmware by the maintenance utility).FLASH FORMAT is executed by using the maintenance utility.If the symptom doesn't change, replace the M32 board.
Code: 072
Display: Service call 072: Error
Description: Engine I/F Error I/F Error between PU and CU
Remedy: Replace M32 board
Code: 073
Display: Service call 073: Error
Description: Video Error When the image data sprads, defect is detected. (Incorrect data receive)
Remedy: Does the error recur? Yes Change the PC to high spec or lower the resolution, and then print again. Replace M32 board