Code: 167

Display: Service call 167: Error
Description: Thermistor Slope Error
Remedy: Is the error message displayed? Does the error recur?
Turn on the power supply again Turn on the power supply again after storage for 30 minutes.

Code: 168

Display: Service call 168: Error
Description: Compensation. Thermistor Error
Remedy: Is the error message displayed? Does the error recur?
Turn on the power supply again Turn on the power supply again after storage for 30 minutes.

Code: 169

Display: Service call 169: Error
Description: Upper Side Thermistor Error
Remedy: Is the error message displayed? Does the error recur?
Turn on the power supply again Turn on the power supply again after storage for 30 minutes.

Code: 170, 171

Display: Service call 170: Error - 171: Error
Description: Thermistor Short circuit / Open circuit of the fuser is detected
Remedy: Does the error recur? Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.

Code: 172, 173

Display: Service call 172: Error - 173: Error
Description: Thermistor Temperature abnormality (high or low) of the fuser is detected
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.

Code: 174

Display: Service call 174: Error
Description: The short circuit of the backup roller. Thermistor is detected. (For the high temperature)
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.

Code: 175

Display: Service call 175: Error
Description: The open circuit of the backup roller. Thermistor is detected. (For the low temperature)
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.

Code: 176, 177

Display: Service call 176: Error - 177: Error
Description: Temperature abnormality (high or low) of the backup Laura thermistor was detected
Remedy: Does it become an error again? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board