Remedy: Does the error recur? Yes Turn on the power supply again. Install an additional RAM DIMM.
Code: 200, 201, 202
Display: Service call 200: Error - 202: Error
Description: PU Firmware Download Error
Remedy: Error occurs when the PU firmware is rewritten After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Description: CU program trouble (203~214 are not generated in usual operation)
Remedy: Incorrect processing is performed by the CU program. Does the error recur? Turn on the power supply again. Replace M32 board.
Code: 209
Display: Service call 209: Down Load Error
Description: Custom Media Type table download failure
Remedy: Failed in downloarding Custom Media Type Table After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Code: 230
Display: Service call 230: Error
Description: RFID Reader not Installed
Remedy: RFID Reader Device error. Does the error recur? Check the connenction of the LUM board (RFIS reader/writer board). Replace the LUM board (RFID reader/writer board). Replace the M32 board.
Code: 231
Display: Service call 231: Error
Description: RFID Reader I/F Error An interface error was detected with the RFID reader device. 01: communication error between the RFID reader and the engine PCB. 02:the transcever circuit error of the RFID reader. 03:communication error between the RFID reader and the toner cartridge. 04:the toner cartridge detection error (more than 4).
Remedy: 01: Same as Error 230. 02: Replace the LUM board (RFID reader/writer board). 03: Check the connection of the antenna cable. 04: Check if the number of toner cartridge is correct.
Remedy: If the error occurs again after returning on the power supply, replace the board of the unit.
Code: 905, 906
Display: Service call 905: Error 906: Error
Description: Short circuit error of the Frame thermistor (thermistor defect) is detected
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.