Code: 168

Display: Contact the Service center. 168: Error Note)
Description: Compensation Thermistor Error
Remedy: Is the error message displayed? Does this error recur?
Turn on the power again. After leaving the printer for 30 minutes, turn on the power again.

Code: 169

Display: Contact the Service center. 169: Error Note)
Description: Upper side Thermistor Error
Remedy: Is the error message displayed? Does this error recur?
Turn on the power again. After leaving the printer for 30 minutes, turn on the power again.

Code: 170, 171

Display: Contact the Service center. 170: Error 171: Error Note)
Description: Short-circuit or open-circuit of fuser thermistor is detected.
Remedy: Does this error recur?
Turn on the power again. Replace the fuser unit.

Code: 172, 173

Display: Contact the Service center. 172: Error 173: Error
Description: The fuser thermistor has detected an abnormal temperature (high temperature or low temperature.)
Remedy: Turn on the power again. Does this error recur?
Replace the fuser unit. Replace the low voltage power supply unit.

Code: 174

Display: Contact the Service center. 174: Error
Description: The backup roller thermistor is detected of its short-circuit. (At high temperature)
Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.

Code: 175

Display: Contact the Service center. 175: Error Note)
Description: The backup roller thermistor is detected of its opencircuit. (At low temperature)
Remedy: Does this error recur? Yes Turn on the power again. Replace the fuser unit.

Code: 176, 177

Display: Contact the Service center. 176: Error 177: Error
Description: The backup roller thermistor has detected an abnormal temperature (high temperature or low temperature.)
Remedy: Does this error recur? Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.

Code: 181, 182, 183

Display: Contact the Service center. 181: Error 182: Error 183: Error
Description: Option unit I/F error (181=Duplex Unit, 182=2nd Tray, 183=3rd Tray)
Remedy: Does this error recur? Turn on the power again. Check for sure connection of the connectors. Replace the option unit.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie