Code: 150 ... 153

Display: SERVICE CALL 150:Error ~ 153:Error
Description: ID unit fuse cannot be disconnected. (150 = Y, 151 = M, 152 = C, 153 = K)
Remedy: Is ID unit setting proper? Does error reoccur? Is error recovered by replacing PRT board?
Reset ID unit. Turn power ON again. After check connections of cable between PRT board and PU PCB, replace PRT PCB. Replace PU PCB.

Code: 154

Display: SERVICE CALL 154:Error
Description: Belt unit fuse cannot be disconnected.
Remedy: Is belt unit setting proper? Does error reoccur?
Reset belt unit. Turn power ON again. Check cable connections and, replace PU PCB.

Code: 155

Display: SERVICE CALL 155:Error
Description: Fuser unit fuse cannot be disconnected.
Remedy: Is fuser unit set properly? Does error reoccur?
After cleaning for fuser connector, reset. Turn power ON again. Check cable connections and replace PU PCB.

Code: 160 ... 163

Display: SERVICE CALL 160:Error ~ 163:Error
Description: Error detected by toner sensor. (160 = Y, 161 = M, 162 = C, 163 = K) It does not occure in factory default setting.
Remedy: Is toner cartridge setting? Is toner lock lever setting? Does error reoccur?
Set toner cartridge. Turn a lock lever of toner to a fixed position. Replace toner sensor or assembly.

Code: 167

Display: SERVICE CALL 167:Error
Description: Thermistor Slope Error
Remedy: Is an error message indicated? Is the error issued again?
Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.

Code: 168

Display: SERVICE CALL 168:Error
Description: Compensation Thermistor Error
Remedy: Is an error message indicated? Is the error issued again?
Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.

Code: 169

Display: SERVICE CALL 169:Error
Description: Upper Side Thermistor Error
Remedy: Is an error message indicated? Is the error issued again?
Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.

Code: 170, 171

Display: SERVICE CALL 170:Error 171:Error
Description: Short circuit in fuser thermistor or open detected.
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.