Remedy: Is the CU Assy properly mounted? Does replacement of the CU PCB correct the problem? Properly mount Replace CU PCB. (Must replace EEPROM)
Code: 081
Display: Service Call 081: Error
Description: Parameter Match Check Error Normal Read/Write not possible with EEPROM or Flash.
Remedy: Normal Read/Write not possible with EEPROM or Flash. If the condition does not change replace CU PCB.
Code: 096
Display: Service Call 096: Error
Description: Finisher Unrestorable Error
Remedy: Is the error display reproducible? If turning OFF and ON the power again does not correct the problem, maintenance by a servicing personnel is necessary.
Code: 097
Display: Service Call 097 Error
Description: Inverter power supply Error
Remedy: Is the error display reproducible? If turning OFF and ON the power again does not correct the problem, maintenance by a servicing personnel is necessary.
Code: 102
Display: Service Call 102: Error
Description: After turning ON the power, Error is detected in engine RAM Read/Write.
Remedy: Does the Error take place again? Replace Engine Control PCB (S2V)
Code: 103
Display: Service Call 103: Error
Description: When turning ON the power, detected Engine SRAM Read / Write Error.
Remedy: Does the Error take place again? Replace Engine Control PCB (S2V)
Code: 104
Display: Service Call 104: Error
Description: When turning ON the power, detected error in engine EEPROM test total.
Remedy: Does the Error take place again? Replace engine control PCB (S2V).
Code: 105
Display: Service Call 105: Error
Description: When turning ON the power, failed to detect the EEPROM (presence).
Remedy: Is there an EEPROM? Does the Error take place again? Check to see if there is an EEPROM. If not, mount an EEPROM. Replace engine control PCB (S2V).