Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Leave for 30 minutes then turn ON power again.
Code: 169
Display: Service Call 169: Error
Description: Upper Side Thermistor Error
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Leave for 30 minutes then turn ON power again.
Description: Fuser Thermistor shortcircuit or Open is detected (High Temperature (HOT) or Low Temperature (COLD))
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Leave for 30 minutes then turn ON power again.
Code: 172, 176
Display: Service Call 172: Error 176: Error
Description: Thermistor indicates High Temperature (HOT) Error.
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Leave for 30 minutes then turn ON power again
Code: 173, 177
Display: Service Call 173: Error 177: Error
Description: Thermistor indicates Low Temperature (COLD) Error.
Remedy: 1) Is an Error message displayed? Yes Turn ON power again. 2) Does the Error take place again? Yes Leave for 30 minutes then turn ON power again.
Code: 179
Display: Service Call 179: Error
Description: Wrong Fuser Standard
Remedy: 1) Is the model and power voltage of the fuser mounted proper? No Assemble proper fuser. Yes Check to see that the fuser is properly assembled. 2) Fuser is properly mounted, but Error results again. Yes Replace fuser.
Code: 187
Display: Service Call 187: Error
Description: Communication with control panel failed.
Remedy: Is the control panel and cable connected properly? No Connect properly Yes Replace the control panel and cable.
Code: 188
Display: Service Call 188: Error
Description: Sub-CPU I/F Error
Remedy: Sub-CPU Communication Error Check the connection of the S2P board. Replace the S2P board.