Remedy: Error of the fan in the duplex unit. Does the error still occur after rebooting? Yes Check to confirm that the duplex unit is mounted correctly. Check the connection of the fan. Yes Replace the fan.
Description: Duplex 24V Abnormal Current Detection
Remedy: 24 V of power is not supplied to the duplex unit properly. Does the error still occur after rebooting? Yes Check to confirm that the duplex unit is mounted correctly. Yes Check the connection of the fan. Replace the fan.
Remedy: The Y ID unit is not operating properly. Does the error message still appear after rebooting? Yes Check to confirm that the Y ID unit is in position. Replace the Y ID unit. Yes Replace the Y ID motor.
Remedy: The M ID unit is not operating properly. Yes Check to confirm that the M ID unit is in position. Does error message still appear after rebooting? Yes Replace the M ID unit. Replace the M ID motor.
Remedy: The C ID unit is not operating properly. Yes Check to confirm that the C ID unit is in position. Does error message still appear after rebooting? Yes Replace the C ID unit. Replace the C ID motor.
Remedy: The K ID unit is not operating properly. Yes Check to confirm that the K ID unit is in position. Does the error message still appear after rebooting? Yes Replace the K ID unit. Replace the K ID motor.