Code: 200, 201, 202

Display: Service call 200: Error~ 202: Error
Description: PU Firmware Download Error
Remedy: Error has occurred during rewriting of the PU firmware. After turning on the power again, perform downloading again. (This error does not occur during the normal operation because this processing is not carried out.)

Code: 203 ... 214

Display: Re-start the printer. 203: Error 204: Error 207: Error 208: Error 214: Error FOC: Error FFF: Error
Description: CU program error (The error numbers 203 through 214 do not occur under the normal operation.)
Remedy: Illegal processing is executed by the CU program. After turning off the power, check for the normal connection CU/ PU board. Then, turn on the power again.

Code: 209

Display: Re-start the printer. 209: Download Error
Description: Custom Media Type table downloading has failed.
Remedy: Custom Media Type table downloading has failed. After turning on the power again, perform downloading again. (This error does not occur during the normal operation because this processing is not carried out.)

Code: 230

Display: Service call 230: Error
Description: RFID Reader not Installed
Remedy: RFID read device error Does this error recur?
Check for normal connection of the RFID R/W board. Replace the RFID R/W. Replace the CU/PU board.

Code: 231

Display: Service call 231: Error
Description: RFID reader I/F error
Interface error with the RFID reader is detected. 01: Communication error between the RFID reader and the engine circuit boards. 02: Error in the wireless circuit of the RFID reader 03: Communication error between the RFID reader and the toner cartridge. 04: Error is detected in the RFID toner cartridge. (In more than 4)
Remedy: 01: Same as the error no. 230 02: Replace the RFID R/W board. 03: Check for normal connection of the antenna cable. 04: Check if quantity of the toner cartridge is correct or not.

Code: 901 ... 904

Display: Re-start the printer. 901: Error~ 904: Error
Description: Abnormal temperature of belt 901: Shortcircuit 902: Open circuit 903: High temperature 904: Low temperature
Remedy: Is the cable from belt thermistor to the high voltage board connected normally? Does this error recur?
Re-connect the cables normally. Turn on the power again. Replace the belt thermistsor.

Code: 918

Display: Re-start the printer. 918: Error
Description: Duplex FAN Alarm Caution
Remedy: Fan error inside the Duplex unit. Does the error recur when the power is turned off once and back on? Does the error recur when the power is turned off once and back on?
Check if the Duplex unit is installed normally or not. Check if the fans are installed normally or not. Replace the fan.

Code: 922

Display: Re-start the printer. 922: Error
Description: Cyan image drum lock error
Remedy: The C ID does not rotate normally. Does the error display recur when the power is turned off once and back on?
Check if the C ID is installed normally or not. Replace the C ID unit. Replace the C ID motor.