Description: An optional unit for another model was detected. 111: Duplex unit, 112: 2nd Tray, 113: 3rd Tray, 114: 4thTray, 115: 5th Tray, 116: Finisher, 117: Inverter
Remedy: Is the proper optional unit for that model mounted? No Mount the proper optional unit. Check the connection. Then turn ON the power again. No Replace the unit if operations are not restored.
Remedy: 1) Is the PU PCB high voltage power cable properly connected? No Connect properly Yes Check to see if there is any contact-defects in the high voltage system. Replace High Voltage Power Unit 2) Does the Error take place again?
Remedy: Error was detected in each fan. 01: Fuser FAN Error 02: Power FAN Error 03: PU Motor FAN Error 04: Belt FAN Error 05: IDFAN Error 06: Top Cover FAN Error Is the applicable location of the fan connection normal? If the condition does not change. Replace fan.