Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI pro905 — Trang 9/11

Code: 918

Display: Power Off/on 918: Error
Description: Duplex FAN0 Alarm Detection
Remedy: Error of the fan in the duplex unit. Does the error still occur after rebooting? Yes Check to confirm that the duplex unit is mounted correctly. Check the connection of the fan. Yes Replace the fan.

Code: 919

Display: Power Off/on 919: Error
Description: Duplex 24V Abnormal Current Detection
Remedy: 24 V of power is not supplied to the duplex unit properly. Does the error still occur after rebooting? Yes Check to confirm that the duplex unit is mounted correctly. Yes Check the connection of the fan. Replace the fan.

Code: 920

Display: Power Off/on 920: Error
Description: Yellow Image Drum Lock Error
Remedy: The Y ID unit is not operating properly. Does the error message still appear after rebooting? Yes Check to confirm that the Y ID unit is in position. Replace the Y ID unit. Yes Replace the Y ID motor.

Code: 921

Display: Power Off/on 921: Error
Description: Magenta Image Drum Lock Error
Remedy: The M ID unit is not operating properly. Yes Check to confirm that the M ID unit is in position. Does error message still appear after rebooting? Yes Replace the M ID unit. Replace the M ID motor.

Code: 922

Display: Power Off/on 922: Error
Description: Cyan Image Drum Lock Error
Remedy: The C ID unit is not operating properly. Yes Check to confirm that the C ID unit is in position. Does error message still appear after rebooting? Yes Replace the C ID unit. Replace the C ID motor.

Code: 923

Display: Power Off/on 923: Error
Description: Black Image Drum Lock Error
Remedy: The K ID unit is not operating properly. Yes Check to confirm that the K ID unit is in position. Does the error message still appear after rebooting? Yes Replace the K ID unit. Replace the K ID motor.

Code: 924

Display: Power Off/on 924: Error
Description: Tray2 24V Abnormal Voltage Detection
Remedy: 24 V of power is not supplied to tray 2 properly. Check to confirm that tray 2 is mounted correctly.

Code: 925

Display: Power Off/on 925: Error
Description: Tray3 24V Abnormal Voltage Detection
Remedy: 24 V of power is not supplied to tray 3 properly Check to confirm that tray 3 is mounted correctly.