Description: High voltage power supply leak
Detect the HVPS leak for charging.
Code: E3-20
Description: Main motor rotation abnormality
Detect the synchronous error despite the assignment to rotate the main motor. Or detect the motor rotating normally despite the assignment to stop it.
Code: E4-01
Description: Thermistor malfunction
The fuser temperature sensor malfunction.
Code: E4-01
Description: Temperature control failure
Fail to reach the defined temperature within the defined time after the fuser lamp is turned ON.
Code: E4-10
Description: Fan malfunction
Detect the exhaust fan rotating despite the assignment to stop it. Or detect the fan stopped despite the assignment to rotate it.
Code: E5-01
Description: DC24V power supply abnormality
Fail to output DC24V.
Code: E5-04
Description: DC12V power supply abnormality
Fail to output DC12V when ready.
Code: E5-05
Description: Scanner 24V power supply abnormality
Detect an error with the scanner 24V power supply control.