Code :
  • Code: 093
  • Description: The unit is operated under the low-temperature environment which is not covered under warranty.
  • Causes: 1. Thermistor defective (Operation Panel Board).
  • Code: 094
  • Description: Malfunction of drum cartridge.
  • Causes: 1. Mixing Paddle defective. 2. Defective Toner Sensor.
  • Code: 400
  • Description: T1 timer (35+-5 sec.) elapsed without detecting 300 bps signal.
  • Causes: Wrong number is dialled and the START button is pushed. Telephone line is disconnected while dialling. MAIN PCB (Modem) is defective. Receiver is defective. (It may only be transmitting CED)
  • Code: 401
  • Description: DCN was returned from receiver while transmitter is waiting for CFR or FTT.
  • Causes: Your machine's ID Number is not programmed. Possible incompatibility or incorrect Password.
  • Code: 402
  • Description: DCN was returned from receiver while transmitter is waiting for NSF/DIS.
  • Causes: Receiver working in NON-STD mode only. (Possible incompatibility)
  • Code: 403
  • Description: Transmitter had no polling function.
  • Causes: "POLLED=ON" (polling XMT ready) is not set at the transmitter. Document to be transmitted is not placed at the transmitter.
  • Code: 404
  • Description: Transmitter sent NSS (or DCS) followed by TCF three times, but the receiver did not respond. (CFR or FTT is usually returned)
  • Causes: Receiver is defective. (Modem, MAIN PCB, etc.) MAIN PCB is defective. Receiver disconnects line during first NSS (or DCS) is transmitted.
  • Code: 405
  • Description: Transmitter received FTT after it transmitted TCF at 2400bps. Received RTN after communicating at 2400 bps.
  • Causes: Line quality is poor. (TCF is damaged due to line noise) Receiver is defective. (Modem, etc.) MAIN PCB is defective.