Description: Polling is rejected from the remote station.
Causes: No polling original is set.
Description: Polling XMT is rejected.
Causes: No polling original is set.
Description: No response after transmitting 3rd CTC or DCN received.
Causes: Incompatible interface.
Description: No response after transmitting 3rd EOR or received DCN.
Causes: Line is faulty. MAIN PCB is abnormal.
Description: No response to the 3rd RR transmitted or received DCN.
Causes: Remote unit is abnormal.
Description: T5 timer (60 sec.) elapsed without MCF.
Causes: Remote unit is abnormal.
Description: Stopped Transmission after EOR Transmission.
Causes: Line is faulty. MAIN PCB is abnormal.
Description: Timer between frames in phase C has elapsed.
Causes: Defective remote station.