Các lỗi thường gặp

Code :
  • Code: 351
  • Description: ID sensor Vsg test error
    When the ID sensor was checked, the ID sensor output voltage was 5.0V while the PWM signal input to the ID sensor was 0.
  • Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Scanning system defective • High voltage supply board defective • ID sensor dirty • Defect at the ID sensor pattern writing area of the drum
  • Code: 352
  • Description: ID sensor, pattern edge detect error
    The ID sensor pattern edge voltage is detected to be not 2.5V twice consecutively during an 800 ms interval.
  • Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • High voltage supply board defective • Dirty ID sensor • Defect at the ID sensor pattern writing area of the drum
  • Code: 353
  • Description: ID sensor, LED current abnormal at initialization
    • One of the following ID sensor output voltages is detected at ID sensor initialization. 1) Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor. 2) Vsg >= 4.0V when the minimum PWM input (0) is applied to the ID sensor.
  • Causes: • ID sensor defective • ID sensor harness defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Exposure system defective • High voltage supply board defective • Dirty ID sensor
  • Code: 354
  • Description: ID sensor timeout abnormal at adjustment
    Vsg falls out of the adjustment target (4.0 +- 0.2V) at the start of Vsg checking after 20 seconds
  • Causes: • ID sensor defective • ID sensor harness defective • ID sensor connector defective • I/O board (IOB) defective • Exposure system defective • Poor ID sensor connector connection • High voltage supply board defective • Dirty ID sensor
  • Code: 390
  • Description: TD sensor error: Test value abnormal
    The TD sensor output voltage is less than 0.5V or more than 5.0V after 10 consecutive times during copying.
  • Causes: • TD sensor defective • TD sensor not connected or connector damaged • Poor connection between the TD sensor and the I/O board (IOB) • I/O board (IOB) defective • Toner supply defective
  • Code: 391
  • Description: TD sensor error: Auto adjust error
    During automatic adjustment of the TD sensor, output voltage is less than 1.8V or more than 4.8V during TD sensor initial setting.
  • Causes: • TD sensor abnormal • TD sensor disconnected • Poor TD sensor connection • I/O board (IOB) defective • Toner supply defective
  • Code: 395
  • Description: Development output abnormal
    A development bias leak signal is detected. High voltage output to the development unit exceeded the upper limit (65%) for 60 ms.
  • Causes: • High voltage supply board defective • Poor connection at the development bias terminal • Poor connection at the high voltage supply board
  • Code: 401
  • Description: Transfer roller leak detected
    A transfer roller current leak signal is detected.
  • Causes: • High voltage supply board defective • Poor cable connection or defective cable • Transfer connector defective