Code: SC901

Description: Mechanical total counter error
The mechanical counter is not connected.
Causes: • Mechanical total counter defective • Mechanical total counter connector not connected

Code: SC951

Description: F-gate signal error 2
When the IPU has already received the F-gate signal (laser writing start trigger signal), the IPU receives another F-gate signal.
Causes: • SBICU defective

Code: SC953

Description: Scanner image setting error
The settings that are required for image processing using the scanner are not sent from the IPU.
Causes: • Software defective

Code: SC954

Description: Printer image setting error
The settings that are required for image processing using the printer controller are not sent from the IPU.
Causes: • Software defective

Code: SC955

Description: Memory setting error
The settings that are required for image processing using the memory are not sent from the IPU.
Causes: • Software defective

Code: SC956

Description: Scanner setting ID error
The ID that is sent from the IPU for scanner parameter setting is different from expected.
Causes: • Software error

Code: SC957

Description: Scanner return ID error
The ID that is sent from the IPU for the scanner return signal is different from expected.
Causes: • Software error

Code: SC958

Description: Scanner ready ID error
The ID that is sent from the IPU for the scanner ready signal is different from expected.
Causes: • Software error