Description: CSS Communication Error (Japan Only)
The machine sent a report on its condition, but CSS detected an error. There is a problem on the telephone line between the machine location and the CSS center.
Description: MK1 Communication Error 1: No Answer to ACK
The optional counter device did not send an ACK signal 100 ms after one frame was sent, even after the same data was sent 3 times.
Causes: • Check the serial line harnesses and connectors at the counter device, the relay board, and the controller. • Replace the counter device. • Replace the MCU.
Description: MK1 Communication Error 2: BREAK Received
A LOW break signal was received while the optional counter device was connected to the communication circuit.
Causes: • Check the serial line harnesses and connectors at the counter device, the relay board, and the controller. • Replace the counter device. • Replace the MCU.
Description: Software Error 1: SCU
There was an unusual operation by the software because of: • An incorrect argument in the program. • An incorrect internal parameter. • Work memory not sufficient. • An error occurred that could not be detected by other SC codes.
Causes: • Set the main power switch to .off. then to .on.. • Go into the SP mode. • Input .0. for SP7405 to display the data for SC991, which includes the software file name, line number, and variable.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.