Description: Polygon motor error 3: XSCRDY signal error
The XSCRDY signal did not go HIGH (Inactive) after the polygon motor had been rotating normally for 200 ms.
Causes: • Polygon motor drive board I/F harness loose, disconnected, or damaged • Polygon motor drive board defective • Polygon motor defective
Description: Polygonal Mirror Motor Error 4: Unstable Timeout
The XSCRDY signal is detected LOW) (Active) after the polygonal mirror motor switches on, but the signal is not detected LOW after 1 s has elapsed, and not detected after another 500 ms has elapsed.
Causes: • I/F harness of the polygonal mirror motor disconnected or defective. • Polygonal mirror motor or polygonal mirror motor driver defective. • Polygonal mirror motor drive pulse is not output incorrectly.
Description: ID sensor pattern test error
One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern. 1) Vsp >= 2.5V 2) Vsg <= 2.5V 3) Vsp = 0V 4) Vsg = 0V
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • High voltage supply board defective • ID sensor dirty • Defect at ID sensor pattern writing area of the drum
Description: ID sensor Vsg test error
When the ID sensor was checked, the ID sensor output voltage was 5.0V while the PWM signal input to the ID sensor was 0
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Scanning system defective • High voltage supply board defective • ID sensor dirty • Defect at the ID sensor pattern writing area of the drum
Description: ID sensor, pattern edge detect error
The ID sensor pattern edge voltage is detected to be not 2.5V twice consecutively during an 800 ms interval.
Causes: • ID sensor defective • ID sensor connector defective • Poor ID sensor connector connection • I/O board (IOB) defective • High voltage supply board defective • Dirty ID sensor • Defect at the ID sensor pattern writing area of the drum
Description: ID sensor, LED current abnormal at initialization
One of the following ID sensor output voltages is detected at ID sensor initialization. 1) Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor. 2) Vsg >= 4.0V when the minimum PWM input (0) is applied to the ID sensor.
Causes: • ID sensor defective • ID sensor harness defective • ID sensor connector defective • Poor ID sensor connection • I/O board (IOB) defective • Exposure system defective • High voltage supply board defective • Dirty ID sensor
Description: ID sensor timeout abnormal at adjustment
Vsg falls out of the adjustment target (4.0 ± 0.2V) at the start of Vsg checking after 20 seconds
Causes: • ID sensor defective • ID sensor harness defective • ID sensor connector defective • I/O board (IOB) defective • Exposure system defective • Poor ID sensor connector connection • High voltage supply board defective • Dirty ID sensor
Description: TD sensor error: Test value abnormal
The TD sensor output voltage is less than 0.5V or more than 5.0V after 10 consecutive times during copying.
Causes: • TD sensor defective • TD sensor not connected or connector damaged • Poor connection between the TD sensor and the I/O board (IOB) • I/O board (IOB) defective • Toner supply defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.