Các lỗi thường gặp

Code :
  • Code: 572
  • Description: Oil overflow sensor error
    The oil overflow sensor power is turned off. The oil overflow sensor does not detect the oil overflow condition.
  • Causes: • Defective oil overflow sensor • Defective harness • Defective BICU
  • Code: 620
  • Description: ADF communication error
    The ADF has been detected. A communication error has occurred.
  • Causes: • Loose connection • Defective ADF • Defective BICU board • Defective scanner I/O board • External noise
  • Code: 630
  • Description: CSS communication error
    The machine tries to communicate with one of the terminals of a relevant service center. An error signal returns.
  • Causes: • Communication error on the public telephone network (logged only; the machine can still operate)
  • Code: 632
  • Description: MF accounting device error 1
    The machine sends a data frame. No normal end signal returns. This symptom happens three times.
  • Causes: • Defective or broken line between machine and device
  • Code: 633
  • Description: MF accounting device error 2
    The machine is communicating with the accounting device. The break signal returns.
  • Causes: • Defective or broken line between machine and device
  • Code: 634
  • Description: MF accounting device error 3
    A backup RAM error is reported from the accounting device.
  • Causes: • Defective accounting device controller • Defective battery in the accounting device
  • Code: 635
  • Description: MF accounting device error 4
    A battery voltage error is reported from the accounting device.
  • Causes: • Defective accounting device controller • Defective battery in the accounting device
  • Code: 640
  • Description: Engine-to-controller communication checksum error
    While the BICU and controller are communicating, a checksum error has occurred.
  • Causes: • Logged only; the machine can still operate