Description: 2nd transfer (paper transfer) electric leakage (–)
Paper transfer starts. The negative (–) output is at the minimum PWM duty value. The returning voltage stays at 4.75 V or more for 60 milliseconds.
Causes: • Short circuit in the paper transfer unit • Defective high voltage supply board • Defective harness (BICU - high voltage supply board)
Code: 412
Description: 2nd transfer (paper transfer) disconnection (+)
The returning voltage N from the paper transfer unit is detected for 180 ms. N <= 1/2 output value
Causes: • Right cover not closed • Defective transfer roller contact mechanism • Defective high voltage supply board • Defective harness (BICU - high voltage supply board)
Code: 420
Description: Discharge error (fusing bias)
The returning voltage N from the fusing unit is detected for 60 ms. N >= 1/2 output value
Causes: • Fusing bias short circuit • Scratched fusing belt • Defective high voltage supply board • Defective harness (BICU - high voltage supply board)
Code: 421
Description: Discharge plate error
The returning voltage N from the discharge unit is detected for 60 ms. N >= 1/2 output value
Causes: • Short circuit in the discharge plate • Defective high voltage supply board • Defective harness (BICU - high voltage supply board)
Code: 430
Description: Transfer belt cleaning error
The returning voltage N from the discharge unit is detected for 480 ms. N <= 1/2 output value
Causes: • Short circuit in the transfer belt cleaning unit • Defective high voltage supply board • Defective harness (BICU - high voltage supply board)
Code: 440
Description: Main motor error
• The main motor starts. The lock signal does not continue for 0.1 second within 1 second. • The main motor starts. The lock signal is detected and operation proceeds normally. The lock signal is not detected for 0.1 second. • The main motor changes its speed. The lock signal does not continue for 0.1 second within 1 second.
Causes: • Defective main motor • Too much load of the main motor drive
Code: 460
Description: Temperature sensor error
The output is 4.5 V (or higher) or 0.3 V (or lower) for 12 seconds.