Description: AC charge output error 2: M
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Description: AC charge output error 3: C
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Description: AC charge output error 4: Y
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Description: Charge, development error 1: K
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Description: Charge, development error 2: M
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Description: Charge, development error 3: C
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Description: Charge, development error 4: Y
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Description: AC bias charge adjustment error 1: K
An average value of 8 ms/cycle could not be attained for Vpp (AC charge bias) within 15 attempts. -or- The output of the AC charge boosted Vpp over 2.8 kV.
Causes: • Charge roller dirty • Charge roller defective • Bias terminal connection at the PCU receptacle is dirty or defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.