Mã lỗi Ricoh Aficio 345 — Trang 4/11
Code:
Tất cả lỗi (85)
SC 405
SC101
SC120
SC121
SC302
SC304
SC320
SC321
SC322
SC323
SC326
SC327
SC328
SC329
SC350-1
SC350-2
SC350-3
SC350-4
SC350-5
SC360
SC361
SC362
SC365
SC390-1
SC390-2
SC391
SC401-1
SC401-2
SC403
SC440
SC490
SC492
SC493
SC501-1
SC501-2
SC502-1
SC502-2
SC503-1
SC503-2
SC504-1
SC504-2
SC506
SC507
SC510-1
SC510-2
SC541
SC542
SC543
SC545
SC546
SC547
SC548
SC599
SC601
SC602
SC620-1
SC620-2
SC620-3
SC621
SC623
SC624
SC630
SC700
SC701
SC722
SC724
SC725
SC726
SC727
SC729
SC730
SC900
SC951
SC954
SC955
SC959
SC960
SC961
SC962
SC963
SC964
SC980
SC981
SC982
SC990
Description: TD sensor error 2
The TD sensor output voltage is less than 1.8V or more than 4.8V during TD sensor initial setting.
Causes: • TD sensor abnormal • No developer in the development unit
Description: Development bias leak
A development bias leak signal is detected.
Causes: • Poor connection between the development bias terminal and the high voltage supply board • High voltage supply board defective
Description: Transfer roller leak error
Causes: • High voltage supply board defective • Poor connection between the transfer current terminal and the high voltage supply board
Description: Transfer roller open error
The transfer roller current feedback signal is not detected.
Causes: • High voltage supply board defective • Poor connection between the transfer current terminal and the high voltage supply board • Poor PCU connection
Description: Transfer belt position sensor error
The transfer belt position sensor does not activate even if the transfer belt clutch has rotated once.
Causes: • Main motor/drive malfunction • Transfer belt position sensor defective • Poor transfer belt position sensor connection
Description: Main motor lock
A main motor lock signal is not detected within 2 seconds after the main motor turns on.
Causes: • Too much load on the drive mechanism • Main motor defective
Description: Exhaust fan motor lock
An exhaust fan motor lock signal is not detected within 5 seconds after the exhaust fan motor turns on.
Causes: • Too much load on the drive mechanism • Exhaust fan motor defective • Poor fan motor connector connection
Description: Cooling fan motor lock
A cooling fan motor lock signal is not detected within 5 seconds after the cooling fan motor turns on.
Causes: • Too much load on the drive mechanism • Cooling fan motor defective • Poor fan motor connector connection