Description: TD sensor error 2
The TD sensor output voltage is less than 1.8V or more than 4.8V during TD sensor initial setting.
Causes: • TD sensor abnormal • No developer in the development unit
Code: SC391
Description: Development bias leak
A development bias leak signal is detected.
Causes: • Poor connection between the development bias terminal and the high voltage supply board • High voltage supply board defective
Code: SC401-1
Description: Transfer roller leak error
Causes: • High voltage supply board defective • Poor connection between the transfer current terminal and the high voltage supply board
Code: SC401-2
Description: Transfer roller open error
The transfer roller current feedback signal is not detected.
Causes: • High voltage supply board defective • Poor connection between the transfer current terminal and the high voltage supply board • Poor PCU connection
Code: SC403
Description: Transfer belt position sensor error
The transfer belt position sensor does not activate even if the transfer belt clutch has rotated once.
Causes: • Main motor/drive malfunction • Transfer belt position sensor defective • Poor transfer belt position sensor connection
Code: SC440
Description: Main motor lock
A main motor lock signal is not detected within 2 seconds after the main motor turns on.
Causes: • Too much load on the drive mechanism • Main motor defective
Code: SC490
Description: Exhaust fan motor lock
An exhaust fan motor lock signal is not detected within 5 seconds after the exhaust fan motor turns on.
Causes: • Too much load on the drive mechanism • Exhaust fan motor defective • Poor fan motor connector connection
Code: SC492
Description: Cooling fan motor lock
A cooling fan motor lock signal is not detected within 5 seconds after the cooling fan motor turns on.
Causes: • Too much load on the drive mechanism • Cooling fan motor defective • Poor fan motor connector connection