Description: TD sensor Output minimum error [M] [D] Vt is less than the minimum value (0.5) for three times consecutively.
Causes: • Defective connector connection • Decreasing toner density
Remedy: 1. Replace the PCU.
Code: 366
Description: TD sensor: Output minimum error [C] [D] Vt is less than the minimum value (0.5) for three times consecutively.
Causes: • Defective connector connection • Decreasing toner density
Remedy: 1. Replace the PCU.
Code: 367
Description: TD sensor: Output minimum error [Y] [D] Vt is less than the minimum value (0.5) for three times consecutively.
Causes: • Defective connector connection • Decreasing toner density
Remedy: 1. Replace the PCU.
Code: 368
Description: TD sensor: Initial control voltage error [K] [D] 1. Vt is less than 1 V even though the control power voltage is adjusted to the maximum. 2. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Code: 369
Description: TD sensor: Initial control voltage error [M] 1. Vt is less than 1 V even though the control power voltage is adjusted to the maximum. 2. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Code: 370
Description: TD sensor: Initial control voltage error [C] 1. Vt is less than 1 V even though the control power voltage is adjusted to the maximum. 2. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Code: 371
Description: TD sensor: Initial control voltage error [Y] 1. Vt is less than 1 V even though the control power voltage is adjusted to the maximum. 2. Vt is more than 1 V even though the control power voltage is adjusted to the minimum.
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Code: 372
Description: TD sensor: Initial adjustment error [K] [D] Vt is not (A ± 0.2) when initial setting for TD sensor is executed. A = SP3011-001 for [K]
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.