Description: Trailing edge laser detection error: [C] [C] The laser synchronizing detection signal for LDB [C] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Laser Synchronizing Detection Error: LDB of the leading edge [K] [D] The laser synchronizing detection signal for LDB [K] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Leading edge laser detection error: [Y] [D] The laser synchronizing detection signal for LDB [Y] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Leading edge laser detection error: [M] [D] The laser synchronizing detection signal for LDB [M] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Leading edge laser detection error: [C] [D] The laser synchronizing detection signal for LDB [C] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: FGATE: On error [K] [C] The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for [K] starts.
Causes: • Defective connection between the controller board and EGB • Defective cable between the EGB and LDB
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Description: FGATE: Off error [K] [C] 1. The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [K] ends. 2. The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective connection between the controller board and EGB • Defective cable between the EGB and LDB
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Description: FGATE: On error [Y] [C] The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [Y] started.
Causes: • Defective connection between the controller board and EGB • Defective cable between the EGB and LDB
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.