Mã lỗi Ricoh Aficio CL4000DN — Trang 7/16
Code:
Tất cả lỗi (125)
195
202
203
204
205
210
211
212
213
220
222
224
226
230
231
232
233
234
235
236
237
240
241
242
243
270
300
301
302
303
304
305
306
307
325
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
380
396
397
400
418
442
452
490
491
531
532
541
542
543
544
545
547
557
670
687
690
818
819
819
819
819
820
820
820
820
820
820
820
820
820
820
820
821
821
822
822
823
823
823
824
827
828
828
829
829
829
850
851
853
854
855
856
857
860
861
863
864
865
866
867
868
870
900
920
921
990
991
992
998
Description: TD sensor: Initial adjustment error [M] [D] Vt is not (A ± 0.2) when initial setting for TD sensor is executed. A = SP3011-002 for [M]
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Description: TD sensor: Initial adjustment error [C]: [D] Vt is not (A ± 0.2) when initial setting for TD sensor is executed. A = SP3011-003 for [C]
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Description: TD sensor: Initial adjustment error [Y]: [D] Vt is not (A ± 0.2) when initial setting for TD sensor is executed. A = SP3011-004 for [Y]
Causes: • Defective connector connection • Defective TD sensor • The toner density in the developer is different from the initial condition.
Remedy: 1. Replace the PCU.
Description: Drum gear position sensor error [C] When receiving the input signal of drum gear position sensor is not correctly done, SC380 is logged.
Causes: • Unclean or defective drum gear position sensor
Remedy: 1 Clean the drum gear position sensor. 2 Replace the drive unit.
Description: Drum motor error [K] [D] The LOCK signal is not detected for 2 seconds more while the start signal of the drum motor for black PCU is output.
Causes: • OPC motor slip due to the excessive load
Remedy: 1. Clean the PCU. 2. Check the cable from the Black OPC/ Development motor. Replace it if necessary. 3. Replace the EGB. 4. Replace the Black OPC/ Development motor.
Description: Drum motor error [CMY] [D] The LOCK signal is not detected for 2 seconds more while the start signal of the drum motor for color PCU is output.
Causes: • OPC motor slip due to the excessive load
Remedy: 1. Clean the PCU. 2. Check the cable from the Black OPC/ Development motor. Replace it if necessary. 3. Replace the EGB. 4. Replace the Black OPC/ Development motor.
Description: ID sensor correction error [D] Regular Vsp is not (4 ± 0.5 V) when ID sensor correction is executed.
Causes: • Defective ID sensors • Dirty ID sensors or transfer belt • ID sensor life is over.
Remedy: 1. Replace the ID sensors.
Description: ID sensor: LED adjustment error [D] LED PWM adjustment is not [A] for three times consecutively. [A] = 50 < [A] < 400
Causes: • Defective ID sensors • Dirty ID sensors or transfer belt • ID sensor life is over.
Remedy: 1. Replace the ID sensors.