Description: [060A-060E] Self-diagnostic error. CPU: Detailed error code Cut-in command does not operate when it is executed
Causes: • Defective CPU devices • Defective ASIC devices
Remedy: 1. Replace the controller board
Code: 820
Description: [0610] Self-diagnostic error. CPU: Detailed error code [0610] Self-diagnostic error. CPU: Detailed error code Timer cut-in does not operate even though it is set.
Causes: • Defective ASIC • Defective devices in which ASIC detects cut-in.
Remedy: 1. Replace the controller board.
Code: 820
Description: [06FF] Self-diagnostic error. CPU: Detailed error code The pipeline clock frequency rate is different from the prescribed value.
Causes: • Defective CPU devices • Mode bit data error, which is used for initialising CPU
Remedy: 1. Replace the controller board
Code: 820
Description: [0702] Self-diagnostic error. CPU: Detailed error code The result when the program is executed in the command cache is different from desirable value.
Causes: • Insufficient CPU cache • Insufficient memory process speed
Remedy: 1. Replace the controller board. 2. Replace the RAM DIMM.
Code: 820
Description: [0709, 070A] Self-diagnostic error. CPU: Detailed error code 820 [D] Even you write the data in the only cache of memory, the data is actually written in another area of memory.
Causes: • Defective CPU devices • Incorrect SPD • Boot mode setting error
Remedy: 1. Replace the controller board. 2. Replace the RAM DIMM.
Code: 820
Description: [0801, 0804, 0807, 0808, 0809, 80A] Self-diagnostic error. CPU: Detailed error code An error occurs when checking the TLB.
Causes: • Defective CPU devices
Remedy: 1. Replace the controller board.
Code: 820
Description: [4002-4005] Self-diagnostic error. CPU: Detailed error code The calculation error in the CPU occurs.