Description: Development motor error 2: M
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the development motor of the affected color.
Causes: • Development motor shaft locked, blocked by and obstruction • DRB (Drive Board) defective
Code: SC326
Description: Development motor error 3: C
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the development motor of the affected color.
Causes: • Development motor shaft locked, blocked by and obstruction • DRB (Drive Board) defective
Code: SC327
Description: Development motor error 4: Y
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the development motor of the affected color.
Causes: • Development motor shaft locked, blocked by and obstruction • DRB (Drive Board) defective
Code: SC336
Description: Developer set error 1: K
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: • Film seal not removed from the black, magenta, cyan, or yellow developer case
Code: SC337
Description: Developer set error 2: M
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: • Film seal not removed from the black, magenta, cyan, or yellow developer case
Code: SC338
Description: Developer set error 3: C
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: • Film seal not removed from the black, magenta, cyan, or yellow developer case
Code: SC339
Description: Developer set error 4: Y
The value of Vcnt is set at the maximum or minimum setting when the TD sensor is initialized.
Causes: • Film seal not removed from the black, magenta, cyan, or yellow developer case
Code: SC340
Description: Toner cartridge set error 1: K
The machine cannot read the ID chip of the black, magenta, cyan, or yellow toner cartridge.
Causes: • Black, magenta, cyan, or yellow toner cartridge set incorrectly