Các lỗi thường gặp

Code :
  • Code: SC341
  • Description: Toner cartridge set error 2: M
    The machine cannot read the ID chip of the black, magenta, cyan, or yellow toner cartridge.
  • Causes: • Black, magenta, cyan, or yellow toner cartridge set incorrectly
  • Code: SC342
  • Description: Toner cartridge set error 3: C
    The machine cannot read the ID chip of the black, magenta, cyan, or yellow toner cartridge.
  • Causes: • Black, magenta, cyan, or yellow toner cartridge set incorrectly
  • Code: SC343
  • Description: Toner cartridge set error 4: Y
    The machine cannot read the ID chip of the black, magenta, cyan, or yellow toner cartridge.
  • Causes: • Black, magenta, cyan, or yellow toner cartridge set incorrectly
  • Code: SC348
  • Description: Toner supply motor error
    2 sec. after the motor START signal is output, a LOCK signal cannot be detected.
  • Causes: • Motor harness disconnected, loose, or defective • Powder pump overload • Sub hopper overload • Toner hopper motor defective
  • Code: SC360
  • Description: TD sensor (Vt high) error 1: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 4.5V for two counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor.
  • Code: SC361
  • Description: TD sensor (Vt high) error 2: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 4.5V for two counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor.
  • Code: SC362
  • Description: TD sensor (Vt high) error 3: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 4.5V for two counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor.
  • Code: SC363
  • Description: TD sensor (Vt high) error 4: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 4.5V for two counts.
  • Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor.