Các lỗi thường gặp

Code :
  • Code: SC364
  • Description: TD sensor (Vt low) error 1: K
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective
  • Code: SC365
  • Description: TD sensor (Vt low) error 2: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective
  • Code: SC366
  • Description: TD sensor (Vt low) error 3: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective
  • Code: SC367
  • Description: TD sensor (Vt low) error 4: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective
  • Code: SC372
  • Description: TD sensor adjustment error 1: K
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 3.2±0.2V
  • Causes: • Film seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Code: SC373
  • Description: TD sensor adjustment error 2: M
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 3.2±0.2V
  • Causes: • Film seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Code: SC374
  • Description: TD sensor adjustment error 3: C
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 3.2±0.2V
  • Causes: • Film seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
  • Code: SC375
  • Description: TD sensor adjustment error 4: Y
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 3.2±0.2V
  • Causes: • Film seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective