Code: SC396

Description: Drum motor error 1: K
When the drum motor of the black, magenta, cyan, or yellow PCU starts, the machine cannot detect a LOCK signal within two sec. The motor is trying to rotate but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • PCU drum dirty • PCU defective • Motor harness defective • Motor control board defective • Drum motor defective • Insufficient lubrication on a drum. Open PCU and apply toner to the drum surface

Code: SC397

Description: Drum motor error 2: M
When the drum motor of the black, magenta, cyan, or yellow PCU starts, the machine cannot detect a LOCK signal within two sec. The motor is trying to rotate but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • PCU drum dirty • PCU defective • Motor harness defective • Motor control board defective • Drum motor defective • Insufficient lubrication on a drum. Open PCU and apply toner to the drum surface

Code: SC398

Description: Drum motor error 3: C
When the drum motor of the black, magenta, cyan, or yellow PCU starts, the machine cannot detect a LOCK signal within two sec. The motor is trying to rotate but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • PCU drum dirty • PCU defective • Motor harness defective • Motor control board defective • Drum motor defective • Insufficient lubrication on a drum. Open PCU and apply toner to the drum surface

Code: SC399

Description: Drum motor error 4: Y
When the drum motor of the black, magenta, cyan, or yellow PCU starts, the machine cannot detect a LOCK signal within two sec. The motor is trying to rotate but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
Causes: • PCU drum dirty • PCU defective • Motor harness defective • Motor control board defective • Drum motor defective • Insufficient lubrication on a drum. Open PCU and apply toner to the drum surface

Code: SC400

Description: ID sensor error 1: Calibration
Before adjustment Vsg_reg<0.5 but Vsg_reg could not be adjusted to the target Vsg_reg = 4.0±0.2V during process control.
Causes: • ID sensor harness disconnected, loose, defective • ID sensor dirty • ID sensor defective • ITB unit drawer connector dirty

Code: SC410

Description: ID sensor error 2: Development γ K
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density not normal: Refer to the procedure for process control self-check error codes 55 to 59 to 59, and 61 (section 4.2.4) • Potential sensor defective • Laser diode not firing • ITB separation for CMY abnormal • Transfer power pack defective • ID sensor defective

Code: SC411

Description: ID sensor error 3: Development γ M
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density not normal: Refer to the procedure for process control self-check error codes 55 to 59 to 59, and 61 (section 4.2.4) • Potential sensor defective • Laser diode not firing • ITB separation for CMY abnormal • Transfer power pack defective • ID sensor defective

Code: SC412

Description: ID sensor error 4: Development γ C
Development gamma for black, magenta, cyan, or yellow is not within range (0.3 to 6.0). Process control halts when this SC is issued.
Causes: • Toner density not normal: Refer to the procedure for process control self-check error codes 55 to 59 to 59, and 61 (section 4.2.4) • Potential sensor defective • Laser diode not firing • ITB separation for CMY abnormal • Transfer power pack defective • ID sensor defective