Các lỗi thường gặp

Code :
  • Code: 521-01-11
  • Description: Bank transport motor error (D158/D159)
    An error code is issued from the paper bank unit.
  • Causes: • Defective bank transport motor • Loose connection • Disconnected or broken harness • Defective bank controller board
  • Code: 530
  • Description: Fusing fan error (D158/D159)
  • Causes:
  • Code: 531
  • Description: QSU fan error (D158/D159)
  • Causes:
  • Code: 532
  • Description: CTL fan error (D158/D159)
    Lock signal is not issued for more than 50 consecutive 100 ms intervals, during fan is rotating.
  • Causes: • Motor overload • Loose connection
  • Code: 541
  • Description: Fusing thermistor open (center)
    The fusing temperature is below 0°C for 5 seconds (detected by the thermistor).
  • Causes: • Fusing thermistor defective or out of position • Loose connectors
  • Code: 542
  • Description: Fusing reload failed (center) (D160/D161/D170)
    NOT reaching the reload temperature in 20 ms after starting fusing lamp control.
  • Causes: • Defective thermistor • Disconnected fusing lamp
  • Code: 542-01
  • Description: Fusing reload failed (center) (D158/D159)
    The fusing temperature rises less than 4 degrees in 2 seconds, and this continues 5 times consecutively.
  • Causes: • Fusing thermistor defective or out of position • Power supply board
  • Code: 542-03
  • Description: Fusing reload failed (center) (D158/D159)
    The fusing temperature does not reach the target within 28 seconds after the fusing lamp controller is activated.
  • Causes: • Broken fusing lamp cablester)