Description: Left exhaust fan motor error (D160/D161/D170) The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: • Loose connection of the exhaust fan motor • Too much load on the motor drive
Code: 591
Description: Rear exhaust fan motor error (D160/D161/D170) The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: • Loose connection of the exhaust fan motor • Too much load on the motor drive
Code: 620
Description: Communication error between BICU and ADF The BICU does not receive a response from the ARDF main board for 4 seconds or more. The BICU receives a break signal from the ARDF main board.
Causes: • Poor connection between the BICU and ARDF main board (DF connector) • ARDF main board • BICU defective
Code: 621
Description: ADF connection error (D160/D161/D170) An incorrect ARDF is detected. An ARDF (including the correct ARDF) is installed while the copier is in the energy saver mode.
Causes: • ARDF incorrect • The connector of the ARDF is installed while the machine is in the energy saver mode.
Code: 622
Description: Paper Bank communication error An error occurs during line connection. A communication error report is received from the UART.
Causes: • The paper bank's control board is faulty. • Defective BCU/IOB • The paper bank's connection is faulty.
Code: 632
Description: Accounting error 1 An error is detected during the communication with the MF accounting device.
Causes: • Accounting device • Loose connection
Code: 634
Description: Accounting RAM error An error is detected in the RAM that saves the information on the MF accounting.
Causes: • Accounting device
Code: 635