Description: Communication Error between BICU and SBU The BICU board cannot detect the SBU connect signal.
Causes: • The flat cable between the BICU board and the SBU has a poor connection • The flat cable between the BICU board and the SBU is damaged • BICU board • SBU
Code: 161-01
Description: IPU (BICU) error (LSYNC error) (D158/D159) Error was detected in the result of the BICU self-check at startup.
Causes: • Defective BICU • Bad cable connection between the SBU and the BICU.
Code: 161-02
Description: IPU (BICU) error (RI response error) (D158/D159) Error was detected on access to the RL
Causes: • Defective BICU
Code: 165
Description: Unauthorized copy protection Failed (D158/D159) Detected the wrong type of copy data protection unit, or no unit was found when copy protection was turned on, or a problem was detected with the unit at startup.
Causes: • Copy data protection unit not attached firmly. • Defective copy data protection unit
Code: 195
Description: Serial number mismatch Checking if the serial number matches.
Causes: • Serial numbers (11 digits) do not match.
Code: 202
Description: Polygon motor error : ON timeout When the polygon motor is rotating.
Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor • The polygon motor drive pulse is not released correctly.
Code: 203
Description: Polygon motor error : OFF timeout When the polygon motor is OFF.
Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor • The polygon motor drive pulse is not released correctly.
Code: 204
Description: Polygon motor error : PMRDY_N signal error When the polygon motor is rotating.
Causes: • Defective or disconnected harness to polygon motor • Defective polygon motor