Description: Zero cross waveform signal error The waveform of the zero cross signal was detected out of range.
Causes: • Electrical noise on the power supply line
Code: 559
Description: Consecutive fusing unit paper jams Three consecutive paper jams occurred in the fusing unit. The paper jam counter for the fusing unit reaches 3 times. The paper jam counter clears after the paper feeds correctly. Note: This SC is issued only if SP1159 is set to "1".
Causes: • Remove the paper jam in the fusing unit. • Make sure that the paper path in the fusing unit is clear.
Code: 590
Description: Exhaust fan motor error The CPU detects an exhaust fan lock signal for more than 3.5 seconds.
Causes: • Poor connection of the exhaust fan motor • Too much load on the motor drive
Code: 620
Description: Communication error between IPU and ADF A break occurred in the connection between the IPU and ADF
Description: Communication timeout between BCU and finisher A break (LOW) signal was received from the finisher.
Causes: • Finisher serial cable connection loose, broken • BCU defective • Finisher main board defective • External noise
Code: 632
Description: Key/card counter device error 1 After 1 data frame is sent to the device, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • Serial line from the device to the main machine is unstable, disconnected, or defective
Code: 633
Description: Key/card counter device error 2 During communication with the device, the MCU received a break (Low) signal.
Causes: • Serial line from the device to the main machine is unstable, disconnected, or defective
Code: 634
Description: Key/card counter device error 3 The backup battery of the counter device RAM is low.